ElectroCore Arabia delivers comprehensive services for Medium Voltage (MV) and Low Voltage (LV) switchgear and Ring Main Units (RMU), ensuring safe and reliable power distribution.
Visual, mechanical, and thermal inspections as per SAES-P-XXX / SEC Distribution Standards
Detection of insulation degradation, loose connections, and overheating
Cleaning, lubrication, tightening, and refurbishment of components
Replacement of worn-out contacts, insulators, and auxiliary parts
Mechanical operation tests (open/close/trip)
Interlock verification and safety mechanism checks
Root cause analysis of failures, trip events, and abnormal operations
Verification of protection relays, control wiring, and signaling systems
ElectroCore Arabia specializes in inspection, testing, and overhaul of MV/HV circuit breakers, including Vacuum, SF₆, and Air Circuit Breakers (ACB).
Complete disassembly, inspection, cleaning, and reassembly
Contact wear measurement and replacement
Opening/closing time measurement
Synchronization and travel curve analysis
Micro-ohm testing for contact condition assessment
Insulation resistance (IR), Hi-Pot, and dielectric strength tests
Gas quality testing (moisture, purity)
Leak detection and refilling in accordance with environmental standards
ElectroCore Arabia offers advanced services for testing, commissioning, and validation of protection and control systems, ensuring reliable fault detection and system coordination.
Secondary injection testing
Primary injection testing
Verification of pickup, time delay, and tripping characteristics
Transformer Differential Protection
Restricted Earth Fault (REF)
Overcurrent & Earth Fault Protection
Distance Protection (Transmission Systems)
End-to-end testing during energization
Functional verification of trip circuits and logic schemes
SCADA/DCS integration testing
Interlock, annunciation, and control logic verification
Replacement of electromechanical relays with numerical relays
Digital integration and automation upgrades
ElectroCore Arabia provides comprehensive services for installation, testing, diagnostics, and repair of MV/LV cable systems, ensuring network reliability and reduced downtime.
Insulation Resistance (IR) Test
Very Low Frequency (VLF) Testing for MV cable
Very Low Frequency (VLF) Testing for MV cable
Sheath integrity testing
Time Domain Reflectometry (TDR)
Thumper & acoustic fault detection methods
Precise fault pinpointing
Supply and installation of cable joints and terminations
Heat shrink / cold shrink technology
Compliance with manufacturer and SEC standards
Detection of external damage, moisture ingress, and insulation failure risks
Rapid response fault repair and cable restoration services